Skip to content
Call us: 01276 300351 Specialist fire safety consultancy

FIRE SAFETY (ENGLAND) REGULATIONS 2022

Fire door assessments, surveys and inspections

Fire doors only work if the door, the frame and the wall around them all perform together. We check all three, and explain clearly what needs attention.

ESI: Fire Safety carries out fire door assessments, surveys and routine inspections for businesses, landlords and managing agents. We do not supply or fit fire doors, so our findings are never shaped by a sale.

✓ Independent inspection and advice
✓ Door, frame and surrounding compartmentation
✓ Clear prioritised findings

GET A QUOTE

Tell us about your project

Send us the basics. We will review the project stage, likely scope and next step.

    By submitting this form you agree to be contacted by ESI: Fire Safety about your enquiry. We will not share your details with anyone else.

    Professional memberships, registrations and industry credentials

    The basics

    What is a fire door, really?

    A fire door is not just a heavy door. It is a tested, certified assembly, made up of the door leaf, the frame, the seals, the hinges and the closing device, all designed to work together to hold back fire and smoke for a specific period of time, usually 30 or 60 minutes.

    If any part of that assembly is wrong, damaged, or has been altered, such as a hole drilled for a cable, a missing intumescent seal, or a self-closer that has been disconnected, the whole door can lose its rating even if it still looks fine from a distance.

    This is why fire doors need checking by someone who knows what they are actually looking for, not just whether the door closes.

    Talk Through Your Doors
    Hallway Door Frame Inspection

    Assessor examining the seals, frame and condition of a fire door assembly.

    WHICH SERVICE DO YOU NEED?

    Assessments, surveys and inspections are not the same thing

    These three terms get used interchangeably, but they are different services, suited to different situations.

    Comparison Fire Door Assessment Fire Door Survey Fire Door Inspection
    What it checks Whether the door, frame and surrounding compartment wall are suitable for the job they need to do. May optionally be intrusive, removing architraves to check installation standards and fire stopping around the frame, and always includes checks above suspended ceilings and other voids. A detailed, documented condition check of every door covered by the survey. A routine visual check that the door is in good order and closing properly.
    Typical scope Normally the whole site. A whole building or portfolio, door by door. Whole building, repeated on a set schedule.
    When it's used Establishing suitability across the site, following major works, or reviewing what is in place against the building's original fire strategy. Getting a full picture of condition before planning remedial works. Ongoing compliance, particularly the quarterly duty for buildings over 11m.
    Typical frequency One-off, as needed. One-off or periodic, such as annually. Quarterly for communal doors in scope of the 2022 Regulations.
    What you get Written findings on suitability, with photographs and recommendations. A full door-by-door asset register, with photographs and certification details for every door. An updated check record for each visit, logged against the asset register.

    Not sure which one you need?

    Tell us about your building and we will advise.

    Ask ESI

    THE BIGGER PICTURE

    Why compartmentation and fire stopping matter as much as the door itself

    A fire door only works as part of a wider system. Compartmentation is how a building is divided into fire resisting cells, using walls, floors and doors together, so that a fire stays contained long enough for people to escape and the fire service to respond.

    Fire stopping is what makes that system actually work in practice. Every time a pipe, cable or duct passes through a fire resisting wall or floor, that gap has to be sealed to maintain the wall's rating. An unsealed service penetration can undo the protection of an otherwise good wall, even if the fire door sitting in it is perfect.

    This is why a fire door survey in isolation can miss the real problem. We look at the door, the frame, and the wall around it together, because a good door in a compromised wall is not actually providing the protection it appears to.

    One of the most commonly missed areas is above suspended ceilings. A compartment wall has to carry on through the ceiling void to the structure above, not stop at ceiling height, and it is easy for this to be overlooked during building works or later alterations. Our assessments always check above suspended ceilings for exactly this reason, and may also involve removing architraves to check installation standards and fire stopping behind the frame itself.

    A quick check of certification labels tells you very little on its own. Our approach is a holistic review of the door and the compartmentation around it, not a box-ticking exercise built around certification stickers or a target for how much replacement work we can recommend.

    Ask About Your Building's Compartmentation
    Industrial Pipe Penetration Inspection

    Checking service penetrations through a fire-resisting wall

    Who it applies to

    Does your building need fire door checks?

    If your building has fire doors, which almost all non-domestic buildings and multi-occupied residential buildings do, you have a duty to keep them in good working order. For residential buildings over 11 metres, the Fire Safety (England) Regulations 2022 go further, requiring quarterly checks of communal fire doors and annual best-endeavours checks of flat entrance doors.

    Offices

    Blocks of flats

    HMOs

    Care settings

    Hotels

    Warehouses

    Schools

    Places of worship

    Holiday accommodation

    Public venues

    Licensed premises

    Not sure what your building needs?

    Tell us a little about the premises and we’ll help you understand the right next step.

    Ask ESI

    WHO IS RESPONSIBLE

    Who arranges fire door checks?

    This is the Responsible Person, whether that is an employer, a building owner, a landlord or a managing agent. For residential buildings, this is often a managing agent acting on the freeholder's behalf, coordinating access to individual flat entrance doors as well as communal areas.

    Bringing us in to inspect, survey or assess your doors does not transfer that legal responsibility. We give you clear findings and a prioritised way forward, but acting on them remains with you as the Responsible Person.

    Check who's responsible on your site

    RTM & MANAGEMENT COMPANIES

    Support for RTM companies and residents' management companies

    If your building is managed by a Right to Manage company, or a residents' management company, the fire safety duty usually sits with volunteer directors, most of whom have no professional property or fire safety background. That is a genuinely difficult position to be in, particularly if you have recently taken over management from a freeholder or previous agent and are not confident in what you have inherited.

    We can review whatever records exist, tell you honestly where the gaps are, and set out a clear, affordable way forward that your board can put to leaseholders with confidence. Where handover from a previous freeholder or agent has left records incomplete, we can also help establish an asset register from scratch, so you are not starting every renewal or insurance conversation from zero.

    Get support for your RTM company

    SCOPE OF WORK

    What does ESI examine?

    Exactly what we cover depends on the level of service, but a thorough check typically includes the following.

    Door leaf

    Condition, damage, and whether it matches its certification

    Frame

    Fit, condition and compatibility with the door

    Gaps and seals

    Intumescent and smoke seals, and gaps around the edge

    Hinges and ironmongery

    Correctly rated and in good condition

    Self-closing device

    Whether the door closes fully from any position

    Glazing

    Correctly rated fire-resisting glass, properly fitted

    Signage

    Fire door signage present where required

    Certification labels

    Whether the door's certification can still be verified

    Surrounding wall

    Condition of the compartment wall the door sits within

    Installation standards behind the frame

    Optionally intrusive, removing architraves to check fixing and fire stopping

    Above suspended ceilings

    Checking compartmentation continues through ceiling voids, not just at door height

    Get a scope of work

    The process

    What happens when ESI checks your doors?

    We keep the process clear and practical, from agreeing the right level of check through to a prioritised report and support with what happens next.

    01

    Initial discussion

    We agree which level of service suits your building and needs.

    02

    Review of information

    We look at any plans, previous surveys or certification records.

    03

    Site visit

    We examine each door in the agreed scope in person.

    04

    Assessment of findings

    We weigh up what we found against what is required.

    05

    Report and priorities

    Findings written up clearly, prioritised against your fire strategy.

    06

    Explanation and support

    We talk you through the report and what to do next.

    Ready to get started?

    Get a quote in a couple of minutes, no obligation.

    The deliverable

    What will you receive?

    At the end of the process, you will get a clearly structured written report that includes:

    A door-by-door asset register

    Existing doors that are already satisfactory

    Photographs of each door

    Deficiencies we have identified

    Certification details, where identifiable

    A prioritised action plan

    A description of each door and its location

    Practical, proportionate recommendations

    Findings against the relevant standard

    Information on when to review or re-check

    For assessments and surveys, this becomes a live asset register you can build on over time, rather than a one-off document that goes out of date the moment something changes.

    See what's included
    Report preview Example fire door inspection report preview
    ESI: Fire Safety

    Fire door inspection report

    Sample only

    Fire Door Inspection Report

    Illustrative preview showing how findings can be structured and prioritised.

    Premises Example residential building
    Service Fire door survey
    Asset register Door-by-door record
    Photo evidence Condition documented
    Action plan Priorities made clear

    Example door record

    Communal corridor fire door Location, certification, condition and findings recorded with photographs.
    Action
    Flat entrance fire door Door leaf, frame, seals, closer and surrounding construction reviewed.
    Review

    Prioritised recommendations

    Focused Office Document Review

    Reviewing an existing fire door survey

    INDEPENDENT REVIEW

    Already have a survey from another contractor?

    We are often asked to review a fire door survey or assessment that someone else produced, whether that is to check it is thorough and accurate, or to make sense of a report that raised more questions than it answered.

    Because we do not supply or fit fire doors ourselves, our review is genuinely independent. We are not incentivised to find extra work, and we will tell you plainly if an existing survey is sound rather than second-guessing it for the sake of it.

    Get a Survey Reviewed

    PRIORITISING WORKS

    Prioritised against your fire strategy, not a generic checklist

    Not every deficiency carries the same weight. A missing seal on a door protecting a single storeroom is a different priority to a self-closer that has failed on a door protecting the main escape route. Where a fire strategy exists for the building, we use it to understand how each door fits into the wider fire safety design, so our recommendations are prioritised against what actually matters for that building, not a one-size-fits-all list.

    If you do not currently have a fire strategy, or are not sure whether the one you have is up to date, our Fire Strategies service can help establish that wider picture alongside your fire door work.

    Ask About Prioritising Your Works

    WHAT TO LOOK OUT FOR

    Common fire door defects

    These are some of the issues we see most often. None of them are usually obvious at a glance, which is exactly why a proper check matters.

    COMMON

    Missing or damaged seals

    Intumescent and smoke seals expand in heat to block gaps. Missing or painted-over seals cannot do this.

    COMMON

    Self-closer not closing fully

    A door that does not close completely from any position is not protecting the escape route.

    COMMON

    Excessive gaps around the edge

    Gaps beyond tolerance let smoke and fire past the door before the seals can act.

    SERIOUS

    Unauthorised holes or cuts

    Holes drilled for cables or fittings can break a door's fire rating entirely.

    COMMON

    Non-rated glazing

    Vision panels fitted with standard glass instead of fire-resisting glass compromise the door.

    COMMON

    Missing certification label

    Without a visible or traceable label, a door's fire rating can be difficult to verify.

    COMMON

    Damage to the door leaf

    Splits, dents or panels knocked through can all reduce a door's ability to hold back fire, even if it still closes normally.

    SERIOUS

    Propped or wedged open

    A fire door held open defeats the point of it entirely. This is one of the most common, and most serious, issues we find.

    COMMON

    Frame damage from cable installation

    Cables or conduit run through the frame, rather than around it, can break the frame's fire performance where it matters most.

    SERIOUS

    Damaged compartmentation nearby

    Gaps, unsealed penetrations or damage to the wall around a door can undo its protection, even if the door itself is fine.

    Spotted something that looks like this?

    Get it checked properly rather than guessing.

    Ask ESI

    Jamie Morgan

    Founder & Principal Consultant

    ABOUT ESI

    Why choose ESI: Fire Safety?

    We are a small, specialist, consultancy led team, overseen by Jamie Morgan, who is listed on the Institute of Fire Safety Managers National Fire Risk Assessors Register and holds Level 4 and Level 6 qualifications in fire risk assessment.

    We do not supply or fit fire doors, and we never will. That keeps our findings independent: we have no reason to find more work than is actually needed, and every recommendation we make is about what your building genuinely requires.

    We also look at fire doors as part of the wider building, not in isolation, drawing on the same expertise we bring to fire risk assessments and fire strategies. Our reports are not built around a sales target or a certification checklist. They are built around what will actually keep your building's compartmentation working as intended.

    "We do not supply or fit fire doors. That keeps our findings independent."

    NFRAR

    Registered fire risk assessor.

    Qualifications

    Level 4 and Level 6 fire risk assessment qualifications.

    IFSM

    Professional membership and ongoing industry engagement.

    Talk to Jamie's team

    !

    URGENT FIRE DOOR SUPPORT

    Been told your fire doors don't comply, or issued an enforcement notice?

    These need a fast response. Call our team now for urgent help understanding what's required and getting it resolved.

    Common questions

    Frequently asked questions

    Do I need quarterly fire door checks?

    If you are the Responsible Person for a multi-occupied residential building over 11 metres in height, the Fire Safety (England) Regulations 2022 require quarterly checks of fire doors in communal areas, and annual best-endeavours checks of flat entrance doors. Other buildings do not have this specific quarterly duty, but still need to keep fire doors in efficient working order under the Regulatory Reform (Fire Safety) Order 2005.

    Fire doors are graded by how long they can hold back fire, tested and expressed in minutes. The letters that sometimes follow the number tell you whether the door also controls smoke.

    FD30

    Holds back fire for 30 minutes. Common in general internal doors.

    FD30S

    30 minutes, with smoke seals to control cold smoke too.

    FD60

    Holds back fire for 60 minutes, where more protection is needed.

    FD60S

    60 minutes, with smoke seals included as well.

    FD90

    90 minutes, used in specific higher-risk situations.

    FD120

    120 minutes, reserved for the most demanding applications.

    The "S" suffix matters more than it might seem. Smoke is usually the greater danger in the early stages of a fire, so a door without smoke seals in a location that needs them is not doing its full job, even if the fire resistance rating itself is correct.

    An assessment looks at the suitability of the door, the frame and the surrounding compartment wall, normally across the whole site rather than a single door. It is often carried out following major works, or to review what is in place against the building's original fire strategy. A survey is a detailed, documented condition check across a whole building or portfolio. An inspection is a routine visual check, typically carried out quarterly, that the door is in good order. See the comparison table above for more detail.

    An asset register is a door-by-door record of every fire door covered by an assessment or survey, including its location, photographs, and certification details where these can be identified. It gives you a single, reliable reference point for your fire doors, and forms the baseline that later routine inspections and any remedial works can be checked against, rather than starting from scratch each time.

    Yes. We can work within a range of digital fire door survey and building safety software, including OneTrace and RiskBase, as well as others. Where you or your managing agent already use a particular system, we can generally provide your asset register within it, rather than adding a separate spreadsheet or paper record for you to manage alongside what you already have.

    The golden thread is the requirement, introduced through the Building Safety Act 2022 following the Grenfell Tower Inquiry, to create and maintain accurate, up to date digital information about a building's fire and structural safety throughout its life, from design through to occupation. It applies most directly to higher-risk buildings, but the underlying principle, reliable and accessible records rather than scattered paperwork, is good practice for any building. A digital fire door asset register, kept current through regular surveys and inspections, is a practical contribution to that golden thread, rather than another disconnected report added to a filing cabinet.

    This is a genuine and common difficulty, which is why the Fire Safety (England) Regulations 2022 require flat entrance door checks to be carried out on a "best endeavours" basis rather than an absolute one. In practice, this means giving residents reasonable written notice, explaining why the check matters, and keeping a clear record of the attempts made, so you can evidence that you tried if access could not be arranged. We can help with scheduling and communicating with residents, and we keep a documented record of every attempt as part of the process, which supports your best endeavours position if it is ever queried.

    Both terms describe doors treated as offering some fire resistance without having been tested and certified the way a modern FD30 or FD60 door would be. A notional fire door is typically an older, traditionally built door, such as a solid timber panelled door of a certain thickness, historically assumed to provide a nominal period of fire resistance based on its construction rather than through formal testing. This relies on assumptions rather than evidence, and current good practice is increasingly moving away from relying on notional ratings without proper verification, given how difficult it is to confirm actual performance without testing. If your building has doors like this, it is worth having them properly assessed rather than assuming they still provide the protection they are assumed to.

    Yes, this is something we are asked to do regularly. Because we do not supply or fit fire doors, we can review another contractor's survey independently and tell you honestly whether it is thorough and accurate.

    It depends on the number of doors, the building type, and which level of service you need. Send us some basic details and we will put together a straightforward, honest quote.

    No, and we never will. We only inspect, survey, assess and report. This keeps our findings independent of any commercial incentive to recommend replacement doors.

    This is common, and does not mean the whole door needs replacing. Many issues, such as a failed self-closer or a missing seal, can be repaired rather than requiring a new door. We will tell you clearly what is needed and let you prioritise accordingly.

    Get started

    Arrange your fire door assessment, survey or inspection

    To put together an accurate quote, it helps if you can let us know a bit about your building and doors. Do not worry if you are not sure exactly what you need, we would rather have a conversation and work it out together.

    Do not worry if you cannot answer everything, we would rather have a conversation and work it out together.

    Request a quotation

    Tell us a little about the premises and what has prompted the enquiry.

      Your details
      About your enquiry
      This helps us understand where the work is located.
      By submitting this form, you agree that ESI: Fire Safety can contact you about your enquiry. Your details will be handled in accordance with the Privacy Policy.